Z6_EL9QHKG10GPM20IJGE61AK10O0
Z7_EL9QHKG10GPM20IJGE61AK10S6
Z7_P86CH0O0I0RF10IB06HRVQ0087
Z7_EL9QHKG10GPM20IJGE61AK10S5
Home
>
Century
>
Ductless Mini-Splits
>
Multi-Zone
>
VMH
>
Outdoor Unit
> 55KBTU MULTIZONE INVERTER OUTDOOR
Multi-zone outdoor unit is designed to handle five indoor air handlers Indoor units may be mixed and matched Inverter technology saves an estimated 40% or more on energy consumption over non-inverter models Delivers extra heating capacity; 100% at 0°F
55KBTU MULTIZONE INVERTER OUTDOOR
Detail
55K 5 Zone Heat Pump
Refrigerant
R410A
EER
10.5
Conductor AWG
14G 4 Wire Stranded
Voltage
208/230V-1-60
SEER/HSPF
18.8/9.3
Cooling Capacity BTUH
55,000
Fuse Amps
60
Inverter Technology
Yes
Heating Capacity BTUH
55,000
Wireless Remote
No
Low Ambient Operation
-22°F
Operating Temperature
5° to 122°F cooling, -22° to 75°F heating
Warranty
10 years on compressor, 10 year on parts
CFM
4500
Auto Restart
Yes
Modes
Cooling, heating, dehumidification, fan only
Min. Circuit Ampacity
40
Sound Rating (dBA)
61
Dimensions HxWxD (in.)
52.48x37.48x16.34
Shipping Wt (lbs)
233.03
Test Listing
ETL US and Canada
Certification
AHRI (complete system)
SEER2/EER2
18.8/10.5
No. of Heads
5
Factory Line-Set Charge (ft.)
125
HSPF2
9.3
Item #:
A-VMH55PV-1-CY
Multi-Zone
Detail
55K 5 Zone Heat Pump
Refrigerant
R410A
EER
10.5
Conductor AWG
14G 4 Wire Stranded
Voltage
208/230V-1-60
SEER/HSPF
18.8/9.3
Cooling Capacity BTUH
55,000
Fuse Amps
60
Inverter Technology
Yes
Heating Capacity BTUH
55,000
Wireless Remote
No
Low Ambient Operation
-22°F
Operating Temperature
5° to 122°F cooling, -22° to 75°F heating
Warranty
10 years on compressor, 10 year on parts
CFM
4500
Auto Restart
Yes
Modes
Cooling, heating, dehumidification, fan only
Min. Circuit Ampacity
40
Sound Rating (dBA)
61
Dimensions HxWxD (in.)
52.48x37.48x16.34
Shipping Wt (lbs)
233.03
Test Listing
ETL US and Canada
Certification
AHRI (complete system)
SEER2/EER2
18.8/10.5
No. of Heads
5
Factory Line-Set Charge (ft.)
125
HSPF2